10,000+ HAPPY CUSTOMERS...
  • FAQs
Select category
  • Select category
  • Artificial Eyes
  • Equipments
  • Eye Drape & Eye Shield
  • Fluorescein & Schirmer Strips | Iris Retractor
  • Instruments
    • All Instruments
      • Astigmatism Markers
      • Caliper
      • Cauteries
      • Corneal Markers
      • Curettes
      • Dissectors
      • Fixation Rings
      • Gauge
      • Iris Hooks
      • Knives
      • Lens Expressor
      • Lens Loops
      • Lens Manipulators
      • Markers
      • Muscle Hooks
      • Nuclear Rotator
      • Nucleus Dividers
      • Optic zone markers
      • Phaco Choppers
      • Polishers
      • Retractors
      • Scleral Depressors
      • Spatulas
      • Speculums
      • Spoons
      • Spuds
      • Sterillization Box
    • Cannulas
      • Air Cannulas
      • Anterior Chamber Cannulas
      • Aspirating Cannulas
      • Capsule Polisher Cannulas
      • Cyclodialysis Cannulas
      • Hydrdelineation Cannulas
      • Hydrodissection Cannulas
      • Irrigating Cannulas
      • Irrigating Lens Manipulator Cannulas
      • Irrigating Vectis Cannulas
      • Irrigating-Aspirating Cannulas
      • Lacrimal Cannulas
      • Lasik Cannulas
    • Forceps
      • Capsulorhexis Forceps
      • Chalazion Forceps
      • Cilia Forceps
      • Colibri Forceps
      • Conjunctiva Forceps
      • Corneal Fixation Forceps
      • Corneal Forceps
      • Fixation and Superior Rectus Forceps
      • Foldable IOL Forceps
      • Hoskin Forceps
      • Intraocular Forceps
      • Iris Forceps
      • Jewelers Forceps
      • Lasik Forceps
      • Mosquito Forceps
      • Muscle Forceps
      • Prechop Forceps
      • Suturing Forceps
      • Tissue Forceps
      • Tying Forceps
      • Vitreous Forceps
    • Scissors
  • Intraocular Lenses
    • Disposable Injector & Cartridge
    • Foldable Hydrophilic Square Edge
    • Hydrophobic Foldable
    • Non Foldable (PMMA)
    • PMMA And Advance Capsular Tension Ring (CTR)
    • Three Piece Lenses
  • Micro Surgical Blades
  • Miscellaneous
  • Ophthalmic Solutions
  • Retina Equipments
  • uncategorised
  • Vision Drum/Acuity Chart
Login / Register
0 Wishlist
0 items ₹0.00
Menu
0 items ₹0.00
Browse Categories
  • Intraocular Lenses

    Intraocular Lenses

      • Non Foldable (PMMA) & Capsular Tension Ring(CTR)
      • Foldable Hydrophilic Square Edge
      • Hydrophobic Foldable
      • Three Piece Lenses
      • Disposable Injector & Cartridge
  • Instruments
    • All Instruments

      All Instruments

        • Astigmatism Markers
        • Caliper
        • Cauteries
        • Corneal Markers
        • Curettes
        • Dissectors
        • Fixation Rings
        • Gauge
        • Iris Hooks
        • Knives
        • Lens Expressor
        • Lens Loops
        • Lens Manipulators
        • Markers
        • Muscle Hooks
        • Nucleus Dividers
        • Nuclear Rotator
        • Optic zone markers
        • Phaco Choppers
        • Polishers
        • Retractors
        • Speculums
        • Scleral Depressors
        • Spoons
        • Spuds
        • Spatulas
        • Sterillization Box
    • Forceps

      Forceps

        • Capsulorhexis Forceps
        • Chalazion Forceps
        • Cilia Forceps
        • Colibri Forceps
        • Conjunctiva Forceps
        • Corneal Fixation Forceps
        • Corneal Forcepe
        • Fixation and Supanur Rectus Forceps
        • Foldable IOL Forceps
        • Hoskin Forceps
        • Intraocular Forceps
        • Iris Forceps
        • Jewelers Forceps
        • Lasik Forceps
        • Mosquito Forceps
        • Muscle Forceps
        • Prechop Forceps
        • Suturing Forceps
        • Tissue Forceps
        • Tying Forceps
        • Vitreous Forceps
    • Cannulas

      Cannulas

        • Air Cannulas
        • Anterior Chamber Cannulas
        • Aspirating Cannulas
        • Capsule Polisher Cannulas
        • Cyclodialysis Cannulas
        • Hydrdelineation Cannulas
        • Hydrodissection Cannulas
        • Irrigating Cannulas
        • Irrigating Lens Manipulator Cannulas
        • Irrigating Vectis Cannulas
        • Irrigating-Aspirating Cannulas
        • Lacrimal Cannulas
        • Lasik Cannulas
    • Scissors
    • Needle Holder
    • Lacrimal Instruments
    • Miscellaneous
  • Micro Surgical Blades
  • Eye Drape & Eye Shield
  • Fluorescein & Schirmer Strips | Iris Retractor
  • Ophthalmic Solutions
  • Retina Equipments
  • Artificial Eyes
  • Vision Drum/Acuity Chart
  • Equipments
  • Miscellaneous
  • Home
  • Blog
  • Shop
  • About us
  • Contact us
Hot
Click to enlarge
Home Ophthalmic Solutions Pre Filled Syringes (PFS) 2ml-Visco Elastic
Cellulose & PVA Sponge Spears-Retina Equipments
Cellulose & PVA Sponge Spears-Retina Equipments
Back to products
Distant Vision Drum with Remote-Cyber Charts
Distant Vision Drum with Remote-Cyber Charts

Pre Filled Syringes (PFS) 2ml-Visco Elastic

Pre Filled Syringes (PFS) 2ml are sterile syringes pre-filled with 2ml of viscoelastic substance, such as sodium hyaluronate or hydroxypropyl methylcellulose, commonly used in ophthalmic surgeries to maintain anterior chamber depth, protect corneal endothelium, and facilitate tissue manipulation.

Add to wishlist
Add to quote loading
SKU: CIE-549 Category: Ophthalmic Solutions
Share:
  • Description
Description

Pre-filled syringes containing 2ml of viscoelastic substance

Occugel 2% w/v hydroxypropyl methylcellulose

The ophthalmic viscosurgical device (ovd) is a sterile, isotonic, apyrogenic viscoelastic solution of highly purified, non inflammatory hydroxy propyl methyl cellulose (hpmc) solution with a high molecular weight greater than 80,000 daltons for intraocular use during the surgery of the anterior segment of the eye. For a 2% w/v hpmc solution each ml of solution provides 20mg of hpmc dissolved in balanced salt solution. The viscosity of this solution is 4000 to 5500 cps

Indications:

The OVD is indicated for use as an ophthalmic surgical aid in anterior segment surgical procedures, such as cataract extraction and intraocular lens implantation. The ovd maintains a deep chamber during anterior segment surgery and thereby allowing for more efficient manipulation with significantly less trauma to the corneal endothelium and other ocular tissues.

Contraindications:

At present, there are no known contraindications, when used by a trained ophthalmic surgeon, as indicated.

Warnings:

• Do not use the package if the integrity of the sterile package is compromised

• The OVD is for intraocular use only

• The OVD is for single use only

• The device is not to be placed in the direct sunlight or temperature exceeding 405,5%

• Do not resterilize the device

Storage:

Store at a temperature between 15° celsius and 35° celsius and a relative humidity less than 65%. Protect from freezing. Do not expose containers to direct sunlight.

Supply:
Sterile solution of 2%w/v hydroxypropyl methylcellulose is available in 2 ml ,3 ml pfs in pouch pack. 5 ml vial with pouch in pack of ten.

Related products

Carbachol Intraocular Solution-Carbachol Intraocular Solution

Ophthalmic Solutions
Carbachol Intraocular Solution is a pharmacological agent used in ophthalmology for inducing miosis (pupil constriction) during cataract surgery. It acts on the iris sphincter muscle, reducing pupil size and facilitating surgical access to the lens, ensuring optimal visualization and surgical outcomes.
Add to wishlist
Quick view

Fluorescein Sodium Injection 10% and 20%

Ophthalmic Solutions
Fluorescein Sodium Injection is a diagnostic agent used in fluorescein angiography or angioscopy of the fundus and iris vasculature in ophthalmic practices. It helps in visualizing the blood vessels in the back of the eye to diagnose conditions such as diabetic retinopathy, macular degeneration, and other retinal disorders. Available in concentrations of 10% and 20%, this injection is administered intravenously, and its fluorescent properties illuminate the retinal blood vessels under a specialized light.
Add to wishlist
Quick view

Sodium Hyaluronate- Opthalmic Solution

Ophthalmic Solutions
Sodium Hyaluronate is a viscoelastic solution used in ophthalmology for maintaining anterior chamber depth, protecting corneal endothelium, and facilitating tissue manipulation during intraocular surgeries, such as cataract extraction, corneal transplantation, or glaucoma procedures.
Add to wishlist
Quick view

Trypan blue 0.06% Ophthalmic solution

Ophthalmic Solutions
Trypan Blue 0.06% Ophthalmic Solution is a sterile dye used in ophthalmic surgery for staining the anterior capsule of the lens during cataract surgery. It enhances visualization of the capsule, facilitating capsulorhexis creation and ensuring accurate intraocular lens implantation.
Add to wishlist
Quick view
Hot

Viscoelastic Solution 5ml

Ophthalmic Solutions
Viscoelastic Solution (Hydroxypropyl Methylcellulose 2%) is a high molecular weight, highly purified grade solution designed for use in intraocular injections during anterior segment surgery of the eye. This clear, isotonic, sterile, non-inflammatory, and non-pyrogenic solution ensures the safe and effective maintenance of the anterior chamber depth and protection of periocular tissues.
Add to wishlist
Quick view
    You must select your brand attribute in Theme Settings -> Shop -> Brands

    Discover excellence with Central India Export - your premier destination for quality ophthalmic equipment worldwide. Explore our extensive range of products and experience unparalleled service and reliability.

    6-7, Shri Vardhan Complex Ramdaspeth, Wardha Road, Nagpur-440012 , Maharashtra (India)

    +91 - 712 - 2429168

    +91 - 9822200622

    vaidsandeep100@yahoo.co.in

    cie@cieindia.com

    Quick links
    • Blog
    • Enquiry
    • Shop
    • FAQS
    Copyright © 2024 Central India Export . All Rights Reserved
    payments
    • Menu
    • Categories
    • Intraocular Lenses
    • Instruments
      • All Instruments
      • Forceps
      • Cannulas
      • Scissors
      • Needle Holder
      • Lacrimal Instruments
      • Miscellaneous
    • Micro Surgical Blades
    • Eye Drape & Eye Shield
    • Fluorescein & Schirmer Strips | Iris Retractor
    • Ophthalmic Solutions
    • Retina Equipments
    • Artificial Eyes
    • Vision Drum/Acuity Chart
    • Equipments
    • Miscellaneous
    • Home
    • Blog
    • Shop
    • About us
    • Contact us
    • Wishlist
    • Login / Register
    Shopping cart
    Close
    Sign in
    Close

    Lost your password?

    No account yet?

    Create an Account
    Shop
    0 Wishlist
    0 items Cart
    My account

    WhatsApp us